271 resultats trouvés
Auteur Titre Type [ Année
Filtres: Auteur est Serge Cosnier [Clear All Filters]
Electrogenerated chemiluminescence of poly[(2,2'-bipyridyl)(4-(2-pyrrol-1-ylethyl)-4'-methyl-2,2'-bipyridyl)2]ruthenium (II) film.,
, Electrochem. commun., Volume 12, Number 7, p.905–908, (2010)
Electropolymerized biotinylated poly (pyrrole-viologen) film as platform for the development of reagentless impedimetric immunosensors.,
, Electrochem. commun., Volume 12, Number 2, p.311–314, (2010)
Enhanced direct electron transfer of a multihemic nitrite reductase on single-walled carbon nanotube modified electrodes.,
, Electroanalysis, Volume 22, Number 24, p.2973–2978, (2010)
Enhanced Solid-State Electrochemiluminescence of Tris(2,2'-bipyridyl)ruthenium(II) Incorporated into Electrospun Nanofibrous Mat.,
, Anal. Chem. (Washington, DC, United States), Volume 82, Number 13, p.5892–5896, (2010)
A Glucose BioFuel cell implanted in rats.,
, PLoS One, Volume 5, Number 5, p.No pp. given, (2010)
Immobilization of biotinylated biomolecules onto electropolymerized poly(pyrrole-nitrilotriacetic acid)-Cu2+ film.,
, Electrochem. commun., Volume 12, Number 10, p.1287–1290, (2010)
Label-free femtomolar detection of target DNA by impedimetric DNA sensor based on poly(pyrrole-nitrilotriacetic acid) film.,
, Anal. Chem. (Washington, DC, United States), Volume 82, Number 3, p.1066–1072, (2010)
Label-free impedimetric immunosensor for sensitive detection of atrazine.,
, Electrochim. Acta, Volume 55, Number 21, p.6228–6232, (2010)
Laccase electrodes based on the combination of single-walled carbon nanotubes and redox layered double hydroxides: Towards the development of biocathode for biofuel cells.,
, J. Power Sources, Volume 195, Number 15, p.4714–4717, (2010)
A promising biosensing-platform based on bismuth oxide polycrystalline-modified electrode: Characterization and its application in development of amperometric glucose sensor.,
, Bioelectrochemistry, Volume 79, Number 2, p.218–222, (2010)
Pyrene functionalized single-walled carbon nanotubes as precursors for high performance biosensors.,
, Electrochim. Acta, Volume 55, Number 27, p.7800–7803, (2010)
Reagentless biosensor for hydrogen peroxide based on self-assembled films of horseradish peroxidase/laponite/chitosan and the primary investigation on the inhibitory effect by sulfide.,
, Biosens. Bioelectron., Volume 26, Number 2, p.536–541, (2010)
Adamantane/$\beta$-cyclodextrin affinity biosensors based on single-walled carbon nanotubes.,
, Biosens. Bioelectron., Volume 24, Number 5, p.1128–1134, (2009)
Amperometric biosensor based on the electro-copolymerization of a conductive biotinylated-pyrrole and alginate-pyrrole.,
, Synth. Met., Volume 159, Number 12, p.1117–1122, (2009)
Amperometric biosensors based on biotinylated single-walled carbon nanotubes.,
, J. Nanosci. Nanotechnol., Volume 9, Number 10, p.6042–6046, (2009)
Characterization of Electrogenerated Polypyrrole-Benzophenone Films Coated on Poly(pyrrole-methyl metacrylate) (sic) Optic-Conductive Fibers.,
, Langmuir, Volume 25, Number 17, p.10384–10389, (2009)
Current-free deposition of Prussian blue with organic polymers: towards improved stability and mass production of the advanced hydrogen peroxide transducer.,
, Electroanalysis, Volume 21, Number 3-5, p.409–414, (2009)
Development of a high analytical performance-xanthine biosensor based on layered double hydroxides modified-electrode and investigation of the inhibitory effect by allopurinol.,
, Biosens. Bioelectron., Volume 24, Number 5, p.1171–1176, (2009)
Direct electrochemistry of hemoglobin in poly(acrylonitrile-co-acrylic acid) and its catalysis to H2O2.,
, Sensors Actuators, B Chem., Volume B137, Number 1, p.259–265, (2009)
Electrochemical characterization of biotin functionalized and regular single-walled carbon nanotube coatings. Application to amperometric glucose biosensors.,
, Sens. Lett., Volume 7, Number 5, p.801–805, (2009)
Glucose oxidase immobilized in alginate/layered double hydroxides hybrid membrane and its biosensing application.,
, Anal. Sci., Volume 25, Number 12, p.1421–1425, (2009)
Impedimetric Immunosensor Based on a Polypyrrole-Antibiotic Model Film for the Label-Free Picomolar Detection of Ciprofloxacin.,
, Anal. Chem. (Washington, DC, United States), Volume 81, Number 20, p.8405–8409, (2009)
Label-free detection of cupric ions and histidine-tagged proteins using single poly(pyrrole)-NTA chelator conducting polymer nanotube chemoresistive sensor.,
, Biosens. Bioelectron., Volume 24, Number 5, p.1451–1455, (2009)
A new HRP/catalase biosensor based on microconductometric transduction for nitrite determination.,
, Mater. Sci. Eng. C Mater. Biol. Appl., Volume 29, Number 6, p.1919–1922, (2009)
Non-covalent biofunctionalization of single-walled carbon nanotubes via biotin attachment by $π$-stacking interactions and pyrrole polymerization.,
, Anal. (Cambridge, United Kingdom), Volume 134, Number 12, p.2412–2418, (2009)
Permeability improvement of electropolymerized polypyrrole films in water using magnetic hydrophilic microbeads.,
, Electroanalysis, Volume 21, Number 7, p.887–890, (2009)
Polycrystalline bismuth oxide films for development of amperometric biosensor for phenolic compounds.,
, Biosens. Bioelectron., Volume 24, Number 12, p.3671–3676, (2009)
Poly(methyl methacrylate) conductive fiber optic transducers as dual biosensor platforms.,
, Biosens. Bioelectron., Volume 24, Number 12, p.3683–3687, (2009)
Sensitive and selective xanthine amperometric sensors based on calcium carbonate nanoparticles.,
, Sensors Actuators, B Chem., Volume 136, Number 2, p.510–515, (2009)
The unmediated choline sensor based on layered double hydroxides in hydrogen peroxide detection mode.,
, Sci. China, Ser. B Chem., Volume 52, Number 12, p.2281–2286, (2009)
Aqueous dispersions of SWCNTs using pyrrolic surfactants for the electro-generation of homogeneous nanotube composites. Application to the design of an amperometric biosensor.,
, J. Mater. Chem., Volume 18, Number 42, p.5129–5133, (2008)
Carbon cavity microelectrode for electrical wiring of enzyme by insoluble electroactive species in aqueous media.,
, Electroanalysis, Volume 20, Number 7, p.750–756, (2008)
Characterization of thin poly(pyrrole-benzophenone) film morphologies electropolymerized on indium tin oxide coated optic fibers for electrochemical and optical biosensing.,
, Electrochim. Acta, Volume 53, Number 16, p.5128–5135, (2008)
Design of carbon nanotube-polymer frameworks by electropolymerization of SWCNT-pyrrole derivatives.,
, Electrochim. Acta, Volume 53, Number 11, p.3948–3954, (2008)
Design of new electropolymerized polypyrrole films of polyfluorinated Zn(II) and Mn(III) porphyrins: Towards electrochemical sensors.,
, Mater. Sci. Eng. C Biomim. Supramol. Syst., Volume 28, Number 5-6, p.731–738, (2008)
Detection of carbohydrate-binding proteins by oligosaccharide-modified polypyrrole interfaces using electrochemical surface plasmon resonance.,
, Anal. (Cambridge, United Kingdom), Volume 133, Number 2, p.206–212, (2008)
Electrochemical fabrication of novel fluorescent polymeric film: Poly(pyrrole-pyrene).,
, Electrochem. commun., Volume 10, Number 10, p.1423–1426, (2008)
Electrochemical nitrate biosensor based on poly(pyrrole-viologen) film-nitrate reductase-clay composite.,
, Bioelectrochemistry, Volume 74, Number 1, p.47–51, (2008)
A highly reversible and sensitive tyrosinase inhibition-based amperometric biosensor for benzoic acid monitoring.,
, Sensors Actuators, B Chem., Volume 134, Number 2, p.1016–1021, (2008)
ITO pattern fabrication of glass platforms for electropolymerization of light sensitive polymer for its conjugation to bioreceptors on a micro-array.,
, Talanta, Volume 75, Number 2, p.564–571, (2008)
A new approach for nitrite determination based on a HRP/catalase biosensor.,
, Mater. Sci. Eng. C Biomim. Supramol. Syst., Volume 28, Number 5-6, p.726–730, (2008)
Preparation and characterization of a novel pyrrole-benzophenone copolymerized silica nanocomposite as a reagent in a visual immunologic-agglutination test.,
, Talanta, Volume 75, Number 5, p.1324–1331, (2008)
Recent advances in DNA sensors.,
, Anal. (Cambridge, United Kingdom), Volume 133, Number 8, p.984–991, (2008)
Urease-gelatin interdigitated microelectrodes for the conductometric determination of protease activity.,
, Biosens. Bioelectron., Volume 24, Number 3, p.489–492, (2008)
Amperometric immunosensor for the detection of anti-West Nile virus IgG using a photoactive copolymer.,
, Enzyme Microb. Technol., Volume 40, Number 3, p.403–408, (2007)
Amperometric Immunosensor for the Detection of Anti-West Nile Virus IgG.,
, Anal. Chem. (Washington, DC, United States), Volume 79, Number 22, p.8662–8668, (2007)
Amperometric phenol biosensor based on laponite clay-chitosan nanocomposite matrix.,
, Biosens. Bioelectron., Volume 22, Number 6, p.816–821, (2007)
Calcium carbonate nanoparticles: A host matrix for the construction of highly sensitive amperometric phenol biosensor.,
, Biosens. Bioelectron., Volume 23, Number 5, p.648–654, (2007)
Development of a highly sensitive, field operable biosensor for serological studies of Ebola virus in central Africa.,
, Sensors Actuators, B Chem., Volume 122, Number 2, p.578–586, (2007)
Development of amperometric biosensor for glucose based on a novel attractive enzyme immobilization matrix: Calcium carbonate nanoparticles.,
, Biosens. Bioelectron., Volume 22, Number 8, p.1612–1617, (2007)
Direct electrochemistry and electrocatalysis of hemoglobin entrapped in composite matrix based on chitosan and CaCO3 nanoparticles.,
, Electrochem. commun., Volume 9, Number 4, p.529–534, (2007)
Electrogenerated indium tin oxide-coated glass surface with photosensitive interfaces: Surface analysis.,
, Biosens. Bioelectron., Volume 22, Number 9-10, p.2230–2236, (2007)
Highly sensitive nitrite biosensor based on the electrical wiring of nitrite reductase by [ZnCr-AQS] LDH.,
, Electrochem. commun., Volume 9, Number 9, p.2240–2245, (2007)
Hybrid material based on chitosan and layered double hydroxides: Characterization and application to the design of amperometric phenol biosensor.,
, Biomacromolecules, Volume 8, Number 3, p.971–975, (2007)
Impedimetric immunosensor for the specific label free detection of ciprofloxacin antibiotic.,
, Biosens. Bioelectron., Volume 23, Number 4, p.549–555, (2007)
Laccase immobilization in redox active layered double hydroxides: A reagentless amperometric biosensor.,
, Biosens. Bioelectron., Volume 22, Number 8, p.1733–1738, (2007)
The limiting performance characteristics in bioelectrocatalysis of hydrogenase enzymes.,
, Angew. Chemie, Int. Ed., Volume 46, Number 38, p.7244–7246, (2007)
Recent Advances in Biological Sensors Based on Electrogenerated Polymers: A Review.,
, Anal. Lett., Volume 40, Number 7, p.1260–1279, (2007)
Rutin determination at an amperometric biosensor.,
, Electroanalysis, Volume 19, Number 2-3, p.253–258, (2007)
Self-Assembled Films of Hemoglobin/Laponite/Chitosan: Application for the Direct Electrochemistry and Catalysis to Hydrogen Peroxide.,
, Biomacromolecules, Volume 8, Number 10, p.3041–3046, (2007)
Photoelectrochemical Immunosensor for Label-Free Detection and Quantification of Anti-cholera Toxin Antibody.,
, J. Am. Chem. Soc., Volume 128, Number 30, p.9693–9698, (2006)
A simple strategy based on photobiotin irradiation for the photoelectrochemical immobilization of proteins on electrode surfaces.,
, Mater. Sci. Eng. C Biomim. Supramol. Syst., Volume 26, Number 2-3, p.436–441, (2006)
Improvement of poly(amphiphilic pyrrole) enzyme electrodes via the incorporation of synthetic laponite-clay-nanoparticles.,
, Talanta, Volume 44, Number 12, p.2209–2215, (1997)
Schiff Base Complexes with Covalently Anchored Luminophores: Self-Enhanced Electrochemiluminescence Detection of Neomycin,
, ACS Sens, Volume 7, Issue 10, (20)